J-VALVES · Ball Valve Manufacturer · Wenzhou, China info@j-valves.com +86-13600648865

weixintupian_20250625145546
Home Products Fully Welded Ball Valve Extended Stem

CHINA J-VALVES Offers Various High-quality I ndustrial Ball Valves

J-VALVES, a distinguished professional ball valve manufacturer rooted in China, takes pride in its extensive product portfolio. Our offerings span a wide range, including trunnion-mounted ball valves, floating ball valves, high-temperature ball valves, high-pressure ball valves, metal-sealed ball valves, ultra-low temperature ball valves, DBB ball valves, Three-way And Four-way Ball Valve, and fully welded ball valves. Each product is a testament to our commitment to precision engineering and reliable performance. Meticulously crafted, they are designed to not only meet but exceed the most stringent industrial demands, ensuring stable operation even under extreme conditions. This enables us to provide our clients with high-value services and makes our valves widely sought-after in industries.

 Fully Welded Ball Valve Extended Stem
 Fully Welded Ball Valve Extended Stem
 Fully Welded Ball Valve Extended Stem
 Fully Welded Ball Valve Extended Stem
 Fully Welded Ball Valve Extended Stem
 Fully Welded Ball Valve Extended Stem
A two to sixty inch welded trunnion valve whose extension carries the drive, the seat lines and the cavity drain to one place above ground.
  • J-VALVES-Q667F

  • J-VALVES

库存: 0
Inquire
Add to Basket


Overview of the J-VALVES fully welded ball valve with an extended stemFully welded ball valve with a tall square stem column, two square plates and four small tubes rising to a valve manifold

The photograph on this page shows a valve with a tall square column rising from the top of the body, two square plates threaded onto it, a bracket at mid height, and four small tubes running up beside it to a manifold of needle valves at the top. The page describes the product as a fully welded ball valve with an extended stem, which is accurate and incomplete: the stem is one of five things that have to reach the surface.

That distinction is the whole subject of this page. A buried valve needs its operator above ground, and that is a shaft. It also needs its seat injection points and its cavity drain above ground, and those are tubes. It needs the column to stand up to an operator leaning on it, and that is a bracket and a base flange. Extend only the shaft and the valve can be turned, but it cannot be maintained.

The page lists four extension types, for buried service, low temperature, high temperature and hazardous areas. They are not four lengths of the same part. Each one is a different calculation, and only the first is about depth. This page separates them.


Design and Construction

The body is welded from a forged pipe section and two forged ends, with no body flange and no bolted cover. The ball runs on an upper and a lower trunnion, the seats are piston type and reachable through injection ports at the body, and the stem leaves the body through graphite packing held by a shoulder, exactly as it does on the short stem version of this valve.

The extension begins above that packing. A base flange is bolted to the top of the body, the square column rises from it, and a second plate at the top carries the actuator. In the photograph the column is square in section rather than round, and that is a practical choice: a square section takes a wrench without slipping, it carries a keyed or clamped coupling more simply than a round bar, and it gives a flat face for the mid height bracket to clamp against.

The four tubes are the part that the product name leaves out. Two of them run to the seat injection ports, one to the cavity drain or vent, and the fourth is a spare or a second cavity connection depending on the seat arrangement. Each ends in a needle valve on the top manifold, so that an operator standing at ground level can inject a seat or prove a cavity without opening the excavation.

That arrangement changes what a buried valve is. With a shaft only, the valve is operable and not maintainable, and every seat problem becomes an excavation. With the tubes brought up, the same valve is operable and maintainable from the surface, and the excavation is needed once, at installation, rather than every time a seat weeps.

Seen at that angle, the count is easy. Two tubes leave the body at the seats, and two more leave the body at the top of the shell; all four pass the bracket and end at the manifold. The bracket is clamped rather than welded, which is what allows the column to be shortened later, and the base flange carries four studs, which is what allows the whole assembly to come off the body.

Second view of the same valve, with the base flange, the mid bracket and the injection tubes clear

Four Tubes and a Square Column

The four extension types on the page are worth taking apart because they are usually read as a price list. Buried service sets the length by the depth of cover plus the height of the pit or the kerb box. Low temperature sets it by the frost line: the packing has to sit where the ambient air keeps it above freezing, so the length follows a heat transfer calculation rather than a drawing dimension.

Extension TypeWhat Sets Its LengthWhat Else Has to Reach the Top
Buried serviceDepth of cover plus pit heightInjection tubes, drain, and a protected top
Low temperatureHeight of the frost line above the packingInsulation, and a seal against moisture
High temperatureDistance that keeps the packing below its limitCooling fins, and a heat break in the column
Hazardous or toxicDistance to a place where a person may standRemote operation, and no manual exposure

The high temperature type is the one that is most often confused with the low temperature type, and they are opposites. In cold service the column is there to keep the packing warm by putting it in ambient air. In hot service the column is there to keep the packing cool, and it does that by adding surface and sometimes fins, so that the heat conducted up the shaft is shed before it reaches the gland. The same column, two opposite duties.

The square column earns its shape at long lengths. A tall column is loaded in bending by the weight of the actuator on top and by anything that leans on it, and it is loaded in torsion by the drive. A square section is worse than a round tube in torsion and better in bending stiffness for the same envelope, which is why the photographed unit has a square column with a bracket rather than a slender round bar.

The mid height bracket is the part that makes a long column behave. It shortens the unsupported span, so the column cannot whip when the valve breaks away, and it takes the lateral load off the base flange bolts. On a six metre column the bracket is not an accessory; without it the base flange is a hinge.

The page offers lengths from half a metre to six metres, with specials beyond ten. At that upper end the extension has become a structure, and the number that matters is no longer the length but the torque required at the top of it. A torque quoted at the stem is a torque for a short extension, and a long column turns it into a different requirement for the drive.


Technical Specifications

The table is the build as the page states it, with two rows rewritten. The seat row lists three polymer options by trade name, and trade names do not belong in a specification: the material class does, and the class is what an order should carry.

ItemValue
Size range2 inch to 60 inch, DN 50 to DN 1500
Pressure classClass 150 to Class 2500, PN 20 to PN 420
TemperatureMinus 29 to plus 425 Celsius, carbon steel body
BodyForged A105, or A350 LF2, F304, F316, F51, F53, or API 5L line pipe steel
Body jointsNone, welded shell
BallF304, F316, F51 or F53, with tungsten carbide coating or hardfacing
Ball supportUpper and lower trunnion
StemF304, F316, 17-4PH or nickel alloy 718
Stem sealGraphite packing, in the body
Extension500 to 6000 mm standard, longer to the project drawing
Extension sectionSquare column, base flange and mid height bracket
Column materialF304, F316, or carbon steel with a galvanised finish
Injection tubesSeat sealant and cavity connections, brought to the top manifold
SeatRPTFE as standard, a higher temperature polymer, or metal with graphite
EndsButt weld to ASME B16.25, optional flanged transition
Top connectionBolted pad for gear, electric, pneumatic or hydraulic drive
DesignAPI 6D and ASME B16.34
TestAPI 6D and API 598

Two rows are the ones to read against the photograph. The extension section row says square column with a base flange and a bracket, which is what the image shows, rather than the word stem. And the injection tube row is the one that turns a buried valve from operable into maintainable, and it is the row the product name omits.

The tube row also carries a pressure rating that is easy to overlook. A seat injection line is at line pressure when it is used, so the tube, its fittings and its needle valve are a small pressure system that has to be rated, made up and tested to the same standard as the valve they serve.


Standards and Compliance

API 6D governs the valve, ASME B16.34 the wall and the ratings, and neither says anything about a column six metres tall or a quarter inch tube running beside it. Those are mechanical design and small bore piping, and they are governed by the drawing and by the same pressure test that proves the valve.

DocumentWhat It FixesWhat It Leaves Open
API 6DValve classes, test, marking, cavity reliefThe extension and its tubes
ASME B16.34Wall and ratings of the bodyThe column above the packing
ASME B16.25The weld end profileThe line pipe it meets
API 598Shell and seat testThe test of the injection tubing
ISO 5211The pad and coupling at the driveThe column between pad and body
ASME IXThe weld procedure for the columnWhether the column is welded or bolted

The last row matters more than it looks. On the photographed valve the column is bolted at both ends, with a base flange below and a top plate above, and the mid bracket is clamped rather than welded. That is a maintenance decision: a bolted column can be removed and shortened on site, and a welded one cannot. A welded column is stiffer and cheaper, and it commits the buyer to the length that was drawn.


Manufacturing Process

The body is welded, radiographed and machined as on every valve in this family, and the extension is built as a separate assembly. The column is cut to length, the two plates are machined to fit it, and the coupling that joins the column to the valve stem is made so that it engages the stem square over its full depth rather than on a corner.

The tubes are bent and fitted after the column is in place, because they have to follow the column and clear the bracket. Each tube is made off with a fitting at the body end and a needle valve at the top, and each is proved before the assembly is coated. A tube that leaks at a compression fitting will do it at the worst moment, which is during an injection on a live line.

The assembly is then aligned. The column is set vertical to the body, the top plate is checked square to the column, and the pad is checked flat and on pattern, since a drive mounted on a plate that is not square will bind on the coupling as it turns.

Coating and protection come last. The column is coated with the body, the tubes are protected against abrasion where they pass the bracket, and the top manifold is fitted with caps so that the ports do not fill with grit in transit.

Seat injection tubes being made off and pressure proved on an extended stem valve before coating

Quality Control and Testing

The valve test is the shell and seat test to API 6D and API 598, and it is done before the extension is fitted, so that a leak is not confused with a fitting. The tube system is tested separately at its own rating, with the needle valves closed and the connections plugged.

The extension test is a rotation test and a stiffness check. The column is turned through the full quarter at the operating torque, the free rotation is read at the top, and the bracket is checked for movement under a lateral load applied by hand. A column that moves at the bracket is a column that will whip when the valve breaks away.

Setting is done with the extension in place. The stops are set against the ball, the top plate is marked, and the position indicator is aligned to the ball rather than to the top of the column, because the column winds up under torque and the top leads the ball by an amount that grows with length.

Quarter turn of an extended stem being checked at the top plate with a lateral load applied to the bracket

Applications and Industry Service

The first use is a buried line valve, where the column brings the operator to a pit and the tubes bring the maintenance points with it. Two to sixty inch covers branch isolation through to mainline valves, and the same arrangement serves both.

The second use is a valve below a deck, a road or a bund, where the operator has to be somewhere a person can stand. Those are the cases where the column is longest, where the mid bracket is mandatory, and where the tubes are the difference between a maintainable valve and a valve that has to be dug up.

The valve is the wrong choice where the column would have to pass through a space that cannot take a bracket, and where nobody will maintain the tubes. A tube manifold that is never used is a set of fittings that will seize, and a seized needle valve on a buried valve is worse than no valve at all.

Extended stem valve on a buried line with the column and manifold reaching a pit cover at ground level

Installation, Operation and Maintenance

Installation begins with the foundation and the verticality, not with the valve. The body is set on its bedding, the column is plumbed to the pit opening, and the base flange is bolted without preloading the column. A column pulled into plumb by its base bolts is a column with a bending load built into it before anything is put on top.

The tubes are connected last and labelled first. Each tube should be identified at both ends, because a seat injection line crossed with a cavity drain is a mistake that only shows up when someone injects into the wrong place under pressure. The top manifold is set where a person can reach it from the pit, not where it is convenient for the fabricator.

Operation is at the top, and the readings worth keeping are the turns to travel and the breakaway torque. Maintenance is the packing at the body, the needle valves at the top, and the coating on the column. The tubes have no service item beyond their fittings, which is an argument for making them accessible rather than burying them behind a welded cover.


How to Specify and Order

The lines below are the ones the page leaves open, and the third is the one that decides whether the valve can be maintained at all.

Line on the OrderWhat to WriteWhy It Matters
Extension lengthThe length, and what sets it: depth, frost line, heat, distanceFour types, four calculations
Column sectionSquare or round, with the bracket positionsThe bracket is what makes a long column work
Injection and drain tubesHow many, and where they terminateWithout them the ports stay underground
Tube rating and testThe pressure rating, and the test at that ratingThey carry line pressure when used
Top connectionPad pattern and the drive to be fittedThe pad allows a later change of drive
Drive torqueQuoted at the top of the columnA torque at the stem is not the same number
Column attachmentBolted or welded, and whether it can be shortenedBolted can be altered, welded cannot
CoatingColumn and tubes, with the field joint standardThe column is exposed steel

Read as a whole, the page describes a valve that is separated from its operator by a column, and the column is only the visible half of the assembly. What makes the arrangement work is the four tubes beside it and the bracket that keeps it straight. Extend the shaft alone and the valve opens; extend the tubes with it and the valve can also be kept sealing.


FAQ

Q: What is the difference between an extended stem and an extended assembly?

A: The stem is the shaft that turns the ball. The assembly adds the column that carries the drive, the bracket that keeps the column straight, and the tubes that bring the seat injection points and the cavity drain to the top. A valve with only the shaft extended can be operated from above ground but cannot be maintained from there.


Q: Why are there four tubes beside the column?

A: Two run to the seat injection ports, one to the cavity drain or vent, and one is a second cavity connection or a spare, depending on the seat arrangement. Each ends in a needle valve on a manifold at the top, so that sealant can be injected and the cavity proved from ground level instead of from the bottom of an excavation.


Q: Are the four extension types on the page the same part in different lengths?

A: No. Buried service is set by depth of cover, the low temperature type by the height of the frost line above the packing, the high temperature type by the distance that keeps the packing below its limit, and the hazardous area type by the distance to a place where a person may stand. Only the first is a depth calculation.


Q: Why is the column square rather than round?

A: Because it is loaded in bending by the drive on top and by anything that leans on it, as well as in torsion by the drive. A square section resists bending better within the same envelope, gives a flat face for the clamped bracket, and takes a wrench without slipping. A round tube would be stronger in torsion and weaker against the load that actually bends it.


Q: Do the injection tubes need their own pressure rating?

A: Yes. When a seat is injected the line is at full pressure, so the tube, its fittings and its needle valve form a small pressure system. They have to be rated for that pressure and tested at it, and they should be identified at both ends, because a seat line crossed with a cavity drain is a mistake that only shows up under pressure.

J-VALVES Ball Valves Size Data Sheet(1)J-VALVES Ball Valves Size Data Sheet(2)J-VALVES Ball Valves Size Data Sheet(3)J-VALVES Ball Valves Size Data Sheet(4)J-VALVES Ball Valves Size Data Sheet(5)J-VALVES Ball Valves Size Data Sheet(6)

Hot Products

News

Product News

Urea Plant Ball Valves: The Wetted Path Survives Only While Oxygen Is Being Fed To It

Carbamate at 150 bar and 185 C eats stainless 50 times faster once the passive film starves. The valve cavity is where the oxygen runs out first.

Read More
Urea Plant Ball Valves: The Wetted Path Survives Only While Oxygen Is Being Fed To It
Product News

Stiction: What A Ball Valve Becomes When Nobody Turns It

A valve that stood closed for years has not worn out. The seat has bonded to the ball, and the first stroke is a step, not a ramp. What the trace shows.

Read More
Stiction: What A Ball Valve Becomes When Nobody Turns It
Product News

Molten Salt Ball Valves: The Valve Works at 565 C And Dies at 219 C

Salt freezes at 220 C and decomposes at 565 C. Everything a molten salt ball valve does happens in that 345 kelvin gap, and the gap is not generous.

Read More
Molten Salt Ball Valves: The Valve Works at 565 C And Dies at 219 C
Product News

Direct Air Capture Ball Valves The Vacuum Side Runs The Seal Backwards, And Three Hundred Thousand Strokes Decide The Design

A solid sorbent DAC plant moves 1.3 million cubic metres of air per tonne of CO2, then asks a DN50 ball valve to hold 0.9 bar from the wrong side.

Read More
Direct Air Capture Ball Valves The Vacuum Side Runs The Seal Backwards, And Three Hundred Thousand Strokes Decide The Design

Get In Touch


Have questions or need a custom solution? Our team is ready to assist you.


Contact Us