J-VALVES · Ball Valve Manufacturer · Wenzhou, China info@j-valves.com +86-13600648865

weixintupian_20250625145546
Home Products 14"300LB WCB Two Piece Flange Trunnion Mounted Ball Valve

CHINA J-VALVES Offers Various High-quality I ndustrial Ball Valves

J-VALVES, a distinguished professional ball valve manufacturer rooted in China, takes pride in its extensive product portfolio. Our offerings span a wide range, including trunnion-mounted ball valves, floating ball valves, high-temperature ball valves, high-pressure ball valves, metal-sealed ball valves, ultra-low temperature ball valves, DBB ball valves, Three-way And Four-way Ball Valve, and fully welded ball valves. Each product is a testament to our commitment to precision engineering and reliable performance. Meticulously crafted, they are designed to not only meet but exceed the most stringent industrial demands, ensuring stable operation even under extreme conditions. This enables us to provide our clients with high-value services and makes our valves widely sought-after in industries.

14"300LB WCB Two Piece Flange Trunnion Mounted Ball Valve
14"300LB WCB Two Piece Flange Trunnion Mounted Ball Valve
14"300LB WCB Two Piece Flange Trunnion Mounted Ball Valve
14"300LB WCB Two Piece Flange Trunnion Mounted Ball Valve
14"300LB WCB Two Piece Flange Trunnion Mounted Ball Valve
14"300LB WCB Two Piece Flange Trunnion Mounted Ball Valve
14"300LB WCB Two Piece Flange Trunnion Mounted Ball Valve
14"300LB WCB Two Piece Flange Trunnion Mounted Ball Valve
14"300LB WCB Two Piece Flange Trunnion Mounted Ball Valve
14"300LB WCB Two Piece Flange Trunnion Mounted Ball Valve
A fourteen inch Class 300 two piece flanged trunnion mounted ball valve with a WCB cast body, raised face or ring joint flanges to ASME B16.5, PTFE seat and a worm gear operator. At this size the valve weighs more than the pipe it sits in, so the body has to be carried on its own support and the flange bolts are not a structural member.
  • J-VALVES-Q347F

  • J-VALVES

库存: 0
Inquire
Add to Basket


Overview of the J-VALVES 14 Inch 300LB WCB Two Piece Flange Trunnion Mounted Ball ValveFourteen inch cast carbon steel trunnion ball valve with worm gear operator and two flanged ends

There is a size at which a valve stops being a fitting and becomes a piece of equipment, and for a flanged trunnion valve that point arrives somewhere around the lower end of the fourteen to sixteen inch range. Below it, the valve hangs on its flanges and nobody thinks about it. Above it, the valve is heavier than the pipe it interrupts, and the pipe was never designed to carry it. That change does not appear on any data sheet, which is why it catches projects out.

What happens when it is ignored is slow and easy to misread. The flange studs take the weight as a bending moment, the gaskets see a load that varies along the ring rather than evenly, and the joint passes the shell test because the shell test is short. Then the line runs, cycles thermally, and the joint that was even becomes uneven. This page is about the support, the lift and the alignment, which are the three things that decide whether a fourteen inch valve of this type stays tight.


Design and Construction

Two pieces, one bolted joint. The joint is on the upstream side of the ball, so the end cap comes off towards the pipe and the ball and both seats come out with it. That is the whole maintenance argument for this body style, and it comes with a condition that is easy to miss at this size: the end cap has to travel along the axis before it clears the ball, so the pipe on that side has to be able to give that much room, either by a spool piece or by a flange that can be spread.

The ball is carried on trunnions, which is not a refinement at DN350 but a necessity. A floating ball of this diameter would transfer the whole line force into the downstream seat, and no hand gear could turn it back. The trunnions take that force into the body, and the seats only have to seal. That is also why the operator here is a worm gear rather than a lever: the gear multiplies a small hand input into the torque the stem actually needs.

Size data sheet with the fourteen inch Class 300 row and the full bore passage

Material Options

The body code is WCB, a cast carbon steel, and at fourteen inch casting is the practical route because a forging of this diameter and wall would be a special order rather than a catalogue item. The trade is that a casting has to be inspected for porosity in a way a forging does not, and the parts that matter are the seat pockets and the joint face rather than the general wall. The code on the plate is what the certificate is written against.

The seat is PTFE as standard with reinforced PTFE or PPL listed for higher temperature, and the choice sets the ceiling of the valve rather than the class. The stem and the trunnion are named on the order. Where the service is cold enough to need a low temperature steel, the body code changes and the whole valve is ordered against that code; it is not an upgrade applied to this one.

ComponentStandard MaterialOptional UpgradeService Notes
BodyWCB cast carbon steel, code as stampedlow temperature or stainless casting on ordercast at this diameter rather than forged
Ballcarbon steel with hard facingstainless on ordercarried on trunnions
Trunnionsurface hardened, or 17-4PHnamed on the ordertakes the full line force
Stem17-4PH or equivalentnamed on the orderdriven by the worm gear
Seat ringPTFEreinforced PTFE or PPLsets the temperature ceiling
Body jointone gasketed studded jointnot offered as a welded bodyend cap travels axially
End facingraised face or ring joint to B16.5chosen at ordergroove is cut, not added
Operatorworm gearlever not practical at this sizelift by the body, not the gear


Technical Specifications

The numbers on this valve come from two places and only two. The flange drilling, and whether the face is raised or ring joint, come from the ASME B16.5 Class 300 row at fourteen inch, so the pattern is the one every supplier works to. The face to face comes from ASME B16.10 for a flanged valve of this size, and the built length is dimensioned on the signed general arrangement drawing rather than printed here. What no table supplies is the mass, and on this valve the mass is what the support is designed from. Class 300 is PN 50 in the API 6D code, which converts the rating and says nothing about the drilling.

The number that is not on the data sheet and matters most on this valve is its mass, and it is deliberately not printed here because it changes with the operator, the trim and the end facing. It is quoted with the drawing, and it is the figure the structural engineer needs in order to design the support. A buyer who orders the valve without that figure usually ends up with the support designed after the valve arrives, which is the wrong order.

ItemValue
Nominal size14 inch (DN350)
Pressure classClass 300 (PN 50, the API 6D pressure code)
Body styletwo piece, one gasketed body joint
Ball supporttrunnion mounted
Borefull bore
Body materialWCB cast carbon steel, code as stamped
Ball materialcarbon steel with hard facing
Trunnion materialsurface hardened, or 17-4PH on order
Stem material17-4PH or equivalent, stated on the order
Seat materialPTFE as standard
Seat optionsreinforced PTFE or PPL
End connectionraised face or ring joint flange, ASME B16.5 Class 300
Face to facedimension on the signed GA drawing, held to ASME B16.10
Design standardASME B16.34 and API 6D
Test standardAPI 598 shell and seat test
Test pressureshell 1.5 times and seat 1.1 times the class rating
Temperature rangeminus 29 to plus 425 Celsius, metal temperature
Temperature ceilingset by the seat material, not by the body code
Installation requirementbody supported, flange studs not structural
Lifting pointson the body, never the gear or the stem
End cap travelaxial clearance needed on the joint side
Operationworm gear
Markingsize, class, body code, heat number
DocumentationEN 10204 3.1 on request
Massquoted with the drawing, needed for the support design


Standards and Compliance

The pressure boundary is governed by ASME B16.34, which supplies the minimum wall and the rating at temperature, and the pipeline requirements come from API 6D. At fourteen inch and Class 300 the two agree on the wall and differ in scope: 6D adds the functional tests, the marking and the documentation that a transmission line buyer will ask for. The shell and seat acceptance figures come from API 598, at one and a half times and one and one tenth times the rating.

Nothing in those three documents mentions how the valve is held up, which is the gap this page exists to fill. Support and lifting belong to the piping design and to the installation method statement, not to the valve standard, so a valve that meets every clause of 6D can still be installed in a way that destroys its joints. The standard proves the valve; the installation proves the joint.

RequirementStandardWhat J-VALVES Supplies
Pressure boundaryASME B16.34minimum wall and the Class 300 rating at temperature
Pipeline valveAPI 6Ddesign, testing, marking and documentation
Shell and seat testAPI 5981.5 times the rating for the shell, 1.1 times for the seat
Flange patternASME B16.5 Class 300fourteen inch, raised face or ring joint
Face to faceASME B16.10flanged valve length for the size and class
Pressure codeAPI 6D clause 7.2Class 300 is written PN 50
MarkingAPI 6Dsize, class, body code, heat number
DocumentationEN 10204 3.1issued against the heat number on request
Support and liftingpiping design, not a valve standardthe gap this page exists to fill


Manufacturing Process

The body is cast, cleaned and inspected before any machining, and the first machining operation establishes the joint face and the flange faces as one datum set. The seat pocket is then cut from the joint face so that the pocket is square to the surface it seals against, and the bore is finished from the same setup where the machine allows it. On a casting this size the wall thickness is checked before machining so that a thin section is found while it can still be scrapped rather than after it has absorbed the machining time.

Assembly is the end cap onto the body over a new gasket, the ball and seats already in place, with the studs brought down in a cross pattern until the faces are parallel. The gear operator is fitted and the valve is cycled to settle the seats before it is tested, because a valve tested before it has been cycled can pass and then weep on its first operation. The lifting points on the body are used for that operation and for nothing else.

Machining bay with a large cast body set up so the joint face and flange faces share one datum

Quality Control and Testing

The shell test is done at one and a half times the rating with the valve closed and the body joint under observation, and the seat test follows in both directions at one and one tenth times with the cavity open. On a valve of this size the test stand has to hold the body the way the line will, which means supported, because a body that is only held by its flanges during the test is being tested in a condition it will never see again.

Casting records and the test sheet are read together. The certificate states the heat and what it was, the plate carries size, class, body code and heat number, and the test sheet states what the valve did. Where the project asks for radiographic examination of the casting or for positive material identification, both are written on the order, and both are reported against the heat rather than against the individual valve.

StepWhat Is CheckedStandard or Acceptance
Castingwall thickness before machining, surfacea thin section is found before it is cut
Joint face and flangeflatness and finishone datum set for both
Seat pocketsquare to the joint facecut from the joint face
Assemblyfaces parallel before studs are torquedend cap finds its own position
Shell testbody wall and the joint, valve supportedAPI 598 at 1.5 times the rating
Seat testno visible leakage, both directionsAPI 598 at 1.1 times, cavity open
Gear and cycletravel, stops, operating torquecycled before testing
Marking and massplate data and mass on the drawingmass needed for the support design

Hydrostatic test stand holding a fourteen inch valve on a support with the body joint visible

Applications and Industry Service

This is a line valve at a size where the line is a main rather than a branch: transmission, pump station suction and discharge, tank farm headers, and the isolation points either side of a metering run. The medium is normally clean and the duty is isolation rather than control, so the valve sits at one end of its travel for months. In those places the thing that eventually needs attention is the seat or the gear, not the body.

Two situations point away from this valve. Where the line has to be pigged, check the bore against the pig rather than against the nominal size, because a full bore valve and a reduced bore valve of the same size are different products. And where the valve has to be rebuilt where it stands without spreading a flange, the two piece body cannot give the end cap its axial travel; a top entry body reaches the same trim from above.

Fourteen inch trunnion valves on a header where each body sits on its own structural support

Installation, Operation and Maintenance

The valve is supported under the body, on a bracket or a stand that carries its mass and lets the pipe carry only its own. The flange studs are then free to do the job they were designed for, which is to compress the gasket evenly, and the joint does not have to resist a bending moment that changes with every thermal cycle. The support is designed from the mass quoted with the drawing, and it is installed before the flanges are torqued, not after.

Lifting is by the body, never by the gear operator or the stem, and never by a sling through the bore. The flanges are brought parallel with the pipe flanges before any stud is tightened, using the support to take the weight while the gap is closed, because a fourteen inch raised face cannot pull itself square. After the first thermal cycle the studs are checked again, which is a torque check rather than a re-torque.


How to Specify and Order

The order line needs size, class, body style, body code, bore, seat material, end facing, operator and test standard. On a valve this size it needs two more that are easy to forget: the mass, because the support is designed from it, and the face to face, because the spool piece that gives the end cap its axial travel is cut to it. Both are quoted with the drawing rather than assumed from the tables.

Acceptance reads three documents in a fixed order. The drawing comes first, because it carries the length, the flange pattern, the mass and the joint torque, and those are the numbers that have to match the pipe in the ground. The nameplate is checked against the drawing next: size, class, body code and heat number. The certificate is checked last and against the heat number on the plate, which is what turns a code into a traceable casting. On a valve this size the drawing is also the document that tells the rigger where it may be lifted.


FAQ

Q: Why does a fourteen inch valve need a support if a six inch one does not?

A: Because the mass of the valve grows with the cube of the size while the pipe wall grows more slowly, so at some diameter the valve becomes the heavier of the two things at the joint. Below that point the pipe can carry it without anyone noticing. Above it, the flange studs and gaskets are carrying a bending moment they were never sized for, and the joint fails slowly rather than at the shell test.


Q: What does the support actually attach to?

A: A bracket or stand under the body, sized for the mass quoted with the drawing and for the movement the line is expected to make. It attaches to the valve body or to the pipe immediately beside it, and it is set before the flange studs are torqued so that the weight is taken off the joint while the gap is closed. The support belongs to the piping design, not to the valve standard, which is why no valve certificate mentions it.


Q: Can I lift the valve by the gear operator?

A: No. The gear, the stem and the mounting pad are sized for turning torque, not for the mass of the body, and a sling around the gear will bend the stem or crack the pad before it lifts anything. Lift by the body, using the points provided, and never pass a sling through the bore where it can damage a seat face on the way through.


Q: How much axial room does the end cap need?

A: Enough for the cap to clear the ball on the joint side, which is a dimension on the drawing rather than a rule of thumb. In practice that means the spool piece on that side is cut to suit, or the flange there can be spread. Where neither is possible the valve cannot be rebuilt in place, and a top entry body is the answer rather than a bigger access hatch.


Q: Is a worm gear necessary at this size?

A: Yes in practice. The torque needed to turn a fourteen inch trunnion ball against its seats is far beyond what a lever can give a hand, and the gear is what makes the valve operable by one person. It also holds the ball in position against the seat load, which a lever does through friction alone. The gear adds mass and that mass is part of what the support has to carry.


Q: What flange pattern will the valve have?

A: ASME B16.5 Class 300 at fourteen inch, in raised face or ring joint as ordered. The pattern is fixed by the standard for this size, so the choice left to the buyer is the facing rather than the drilling, and the facing has to be decided before the flange is machined because a ring groove cannot be cut in the field.

J-VALVES Ball Valves Size Data Sheet(1)J-VALVES Ball Valves Size Data Sheet(2)J-VALVES Ball Valves Size Data Sheet(3)J-VALVES Ball Valves Size Data Sheet(4)J-VALVES Ball Valves Size Data Sheet(5)J-VALVES Ball Valves Size Data Sheet(6)

Hot Products

News

Product News

Ball Valves in Amine CO2 Capture: Heat Stable Salts, Rich Amine, And The Three Places The Body Thins

Rich amine at 110 C with heat stable salts is where capture plant ball valves fail. Materials, velocity limits, cavity gas and seat choice, with numbers.

Read More
Ball Valves in Amine CO2 Capture: Heat Stable Salts, Rich Amine, And The Three Places The Body Thins
Product News

Fail-Safe Ball Valve Actuators: Spring Return, Stored Air, And The Torque Nobody Checks

Spring return or stored air? The answer is a torque curve, not a datasheet box. Sizing, receiver volume, closing time and four silent failures.

Read More
Fail-Safe Ball Valve Actuators: Spring Return, Stored Air, And The Torque Nobody Checks
Product News

Ball Valve Stem Leak: The Gland, The Backseat And The Repair That Cannot Be Done Live

A stem leak on a quarter turn valve is four different failures. What gland tightening buys you, why the backseat is usually absent, and what needs a shutdown.

Read More
Ball Valve Stem Leak: The Gland, The Backseat And The Repair That Cannot Be Done Live
Product News

Ball Valves in A Kraft Pulp Mill: Black Liquor, Green Liquor And The Cost of Choosing The Alloy by Habit

White liquor at pH 14 cracks carbon steel welds, black liquor sets solid below 100 C, green liquor dregs grind seats: alloy choice and torque in a kraft mill.

Read More
Ball Valves in A Kraft Pulp Mill: Black Liquor, Green Liquor And The Cost of Choosing The Alloy by Habit

Get In Touch


Have questions or need a custom solution? Our team is ready to assist you.


Contact Us