Home Products Long Stem Ball Valve, Forged Steel Flanged, API 6D, for Buried And Insulated Lines

CHINA J-VALVES Offers Various High-quality I ndustrial Ball Valves

J-VALVES, a distinguished professional ball valve manufacturer rooted in China, takes pride in its extensive product portfolio. Our offerings span a wide range, including trunnion-mounted ball valves, floating ball valves, high-temperature ball valves, high-pressure ball valves, metal-sealed ball valves, ultra-low temperature ball valves, DBB ball valves, Three-way And Four-way Ball Valve, and fully welded ball valves. Each product is a testament to our commitment to precision engineering and reliable performance. Meticulously crafted, they are designed to not only meet but exceed the most stringent industrial demands, ensuring stable operation even under extreme conditions. This enables us to provide our clients with high-value services and makes our valves widely sought-after in industries.

Long Stem Ball Valve, Forged Steel Flanged, API 6D, for Buried And Insulated Lines
Long Stem Ball Valve, Forged Steel Flanged, API 6D, for Buried And Insulated Lines
Long Stem Ball Valve, Forged Steel Flanged, API 6D, for Buried And Insulated Lines
Long Stem Ball Valve, Forged Steel Flanged, API 6D, for Buried And Insulated Lines
Long Stem Ball Valve, Forged Steel Flanged, API 6D, for Buried And Insulated Lines
Long Stem Ball Valve, Forged Steel Flanged, API 6D, for Buried And Insulated Lines
Long Stem Ball Valve, Forged Steel Flanged, API 6D, for Buried And Insulated Lines
Long Stem Ball Valve, Forged Steel Flanged, API 6D, for Buried And Insulated Lines
Long Stem Ball Valve, Forged Steel Flanged, API 6D, for Buried And Insulated Lines
Long Stem Ball Valve, Forged Steel Flanged, API 6D, for Buried And Insulated Lines
Long Stem Ball Valve, Forged Steel Flanged, API 6D, for Buried And Insulated Lines
Long Stem Ball Valve, Forged Steel Flanged, API 6D, for Buried And Insulated Lines
Size Range: 1/2 to 24 inch (DN15 to DN600)
Pressure Class:ASME Class 150 to 2500 / PN20 to PN420
Temperature Range: -29 to 425 degrees C standard, -196 degrees C with extended bonnet and PCTFE seats
Body Material: Forged A105, A105N, A350 LF2, A182 F304, F316, F316L, F51
Ball: F304, F316, F51, or hard chrome / ENP plated
Stem: F316 or 17-4PH, anti blowout
Seat: PTFE, RPTFE, PPL, PEEK, or metal seat
Extension Type: Extended spindle for burial, or extended bonnet for thermal service
Extension Length: 0.6 to 3.0 m typical, set by depth of cover or insulation thickness
Seal Position: Body gland plate for buried type, top of extension for extended bonnet type
End Connection: Flanged RF or RTJ to ASME B16.5 / B16.47
Design Standard: API 6D, API 608, ASME B16.34
Test Standard: API 6D, API 598, ISO 5208
Emission: ISO 15848-1, class on request
Operation: Lever, gear, chain wheel, floor stand, pneumatic, electric
  • Q41F

  • J-VALVES

库存: 0
Inquire
Add to Basket
Ball valves.jpg

A long stem ball valve is a quarter-turn valve whose operating spindle or bonnet is extended beyond the normal height so that the handle or actuator sits clear of a buried pipe, an insulation jacket, a wall penetration or a deep valve pit. The body, ball and seats are ordinary; what changes is that the distance between the media and the operator has been engineered rather than left to the pipe fitter.

That definition hides an important split. In a buried line the extension is a bare spindle inside a sleeve, and the pressure boundary stops at the valve body gland. In a cold box or a heated jacket line the extension is a pressure-retaining bonnet, and the pressure boundary runs all the way up to the packing. Both are sold as long stem valves, and confusing them is the most expensive mistake made in this product family. This page covers both, tells them apart, and then specifies the forged steel flanged version that J-VALVES builds from 1/2 inch to 24 inch in Class 150 to 2500.

Comparison of an extended spindle buried valve and an extended bonnet cryogenic valve

Two Products Sold Under One Name

The search term is the same, the drawings are not.

In the buried arrangement, the valve body sits in the ground with its neck at normal height, and a solid or tubular spindle is bolted to the stem with a coupling and runs up inside a protective sleeve to a valve box at grade. The stem seals stay in the body. The sleeve is not a pressure part. If the seal fails, the leak appears in the valve box at the bottom, not at the surface, which is why buried valves are usually specified with a sealed and drainable box.

In the extended bonnet arrangement, the whole bonnet is lengthened and pressure runs up to the packing at the top. This is the cryogenic configuration, and the length is a thermal device rather than an access device: the metal column between the cold body and the packing keeps the gland above freezing so the packing does not ice up. It is also used on high temperature lines where the packing must sit outside a thick insulation layer.

Characteristic

Extended spindle, buried service

Extended bonnet, thermal service

What is extended

A spindle and a protective sleeve

The bonnet, which is a pressure part

Where the pressure boundary ends

At the body gland plate

At the packing at the top

Seal position

Low, in the body

High, above the insulation

Length set by

Depth of cover and valve box height

Insulation thickness and the heat leak calculation

Typical temperature

Ambient to 200 degrees C

-196 to -50 degrees C, or above 200 degrees C

Failure mode if the seal leaks

Leak appears inside the valve box

Leak appears at the gland, in view

Standard that governs the length

Project specification

BS 6364 for cryogenic, or project specification

J-VALVES builds the forged steel flanged long stem valve in the extended spindle form for buried and insulated lines, and offers the extended bonnet form as a cryogenic variant with PCTFE seats and graphite packing. When a datasheet line reads "long stem ball valve, buried, 800 mm extension", it is the first type. When it reads "extended bonnet, cold box, 250 mm", it is the second. If the enquiry does not say which, the quotation will be wrong by a factor of three.

How the Extension Length Is Determined

Length is the only dimension in this product that is routinely guessed, and it is the one that cannot be corrected later. It is set by four inputs.

The first is the depth of cover. A buried process line is normally laid with 0.9 to 1.5 m of cover to the top of the pipe, and the operator has to reach grade. The extension therefore has to span from the body centreline to the top of the valve box, plus the height of the operating nut or handwheel.

The second is the insulation thickness. A hot line with 80 mm of mineral wool and cladding needs a bonnet that clears 80 mm plus the cladding plus the room to swing a handle. A cold line with 200 mm of PIR or polyurethane needs more, and the figure is measured to the outside of the cladding, not to the pipe.

The third is the operator. A lever needs a clear swing of 90 degrees, which for a 12 inch lever is a swept envelope of about 1.2 m. A gear operator needs handwheel clearance and standing room. An actuator needs its own envelope plus the air line or cable route.

The fourth is thermal growth, and it works in both directions. A carbon steel spindle 1.5 m long at 200 degrees C grows by about 3.5 mm relative to its cold length, using a coefficient of 11.7 microstrain per kelvin. A stainless spindle of the same length grows by about 4.8 mm. That movement has to be absorbed by the coupling or by a sliding joint, otherwise it either lifts the handwheel off its mounting or puts the spindle in compression and bows it.

Application

Typical extension

What sets it

Watch out for

Buried line, road crossing

1.0 to 1.5 m

Depth of cover plus valve box

Box must be drainable and sealed against ground water

Buried line, plant area

0.6 to 1.0 m

Grade level and paving

Vehicle load on the box, not on the spindle

Hot insulation, 50 to 100 mm

150 to 300 mm

Insulation plus cladding plus handle room

Thermal growth of the spindle

Cold insulation, 150 to 250 mm

250 to 400 mm

Insulation plus vapour barrier continuity

Condensation inside the extension

Cryogenic cold box

300 to 600 mm

Heat leak calculation, gland must stay above 0 degrees C

Ice collar forming inside the insulation

Deep pit or chamber

1.5 to 3.0 m

Pit depth plus access

Spindle buckling and guide spacing

The dimension that goes on the drawing is from the body centreline to the operator mounting face, not from the flange. Quoting it any other way invites a mismatch between the valve and the valve box that only becomes visible on site.

The Mechanics Problem Nobody Mentions: Bending and Wind-Up

An extension is a shaft, and a shaft has two properties that get worse with length. Both are calculable, and both are routinely ignored.

The first is lateral stiffness, which falls with the cube of the length. A spindle that is stiff enough at 300 mm becomes visibly flexible at 1.5 m, and a flexible spindle under an off-centre handwheel load bends, rubs on the sleeve, and eventually fatigues at the coupling. The remedy is a guide or steady bearing inside the sleeve at intervals, typically every 20 to 30 diameters, and a sleeve bore that gives running clearance without letting the spindle whip.

The second is torsional wind-up. A long slender shaft twists before it turns the ball, so the handwheel moves through an angle that never reaches the valve. For a solid steel shaft the wind-up angle is 32 times the torque times the length, divided by pi times the shear modulus times the diameter to the fourth power. Put numbers in: a 500 N m torque on a 1.5 m long, 30 mm diameter steel spindle gives about 6.8 degrees of twist. That is tolerable. Halve the diameter to 15 mm and the same torque produces about 109 degrees, which is more than the valve's entire quarter turn, and the spindle is now a spring rather than a shaft.

Spindle diameter

Length 0.5 m

Length 1.0 m

Length 2.0 m

Verdict at 500 N m

20 mm

5 degrees

10 degrees

21 degrees

Acceptable to 1 m, marginal at 2 m

30 mm

1.4 degrees

2.8 degrees

5.7 degrees

Good for all three lengths

40 mm

0.4 degrees

0.9 degrees

1.8 degrees

Stiff, use where the actuator needs a position signal

50 mm

0.2 degrees

0.4 degrees

0.9 degrees

Only where the torque is much higher than 500 N m

The practical rule is a spindle diameter of at least one eighth of the extension length for manual operation, and one sixth where an actuator with position feedback is fitted, because wind-up shows up as a false position signal and drives the actuator into a limit fault.

There is a third effect at large size: the extension is now a column in compression when the valve is being closed against a high differential, and a long thin column buckles. The Euler load for a 30 mm steel spindle 2 m long with pinned ends is in the region of 60 kN, which sounds ample until the handwheel load is applied off-axis and the effective length doubles.

Where the Stem Seals Should Sit

This is the design decision that separates a good buried valve from a bad one, and it is invisible on a datasheet.

If the stem seals are at the top of the extension, then the extension itself is a pressure boundary and every joint in it is a potential leak path. That is the arrangement used on extended bonnet cryogenic valves, where the seal has to be warm and therefore has to be high.

If the stem seals are in the body gland plate at the bottom, the extension carries torque only. The seal stays where the body is rigid, where the machining tolerance is tightest, and where a leak is contained in the valve box rather than spraying at the surface. That is the arrangement used on buried valves, and it is the reason the buried type can have a 3 m extension without becoming a pressure vessel.

The consequence is a maintenance difference worth stating. With the seals in the body, the packing can be renewed by removing the gland plate with the valve in line and the line isolated, without excavating. With the seals at the top, the packing is accessible but the whole extension has to hold pressure, and the body-to-extension joint has to be tested as part of the shell test.

Forged Steel Bodies and What Each Grade Is For

This valve is forged rather than cast, and at 1/2 to 24 inch that is a deliberate choice. A forging has a continuous grain flow, no shrinkage porosity and no possibility of a cold shut, which matters most in the body wall around the seat pocket where a casting defect would be invisible and fatal. It also allows a smaller wall for the same rating, so a forged 8 inch Class 600 valve is lighter than its cast equivalent.

Grade

Standard

Temperature limit

Where it is used

A105

ASTM A182 F/A105

-29 to 425 degrees C

General carbon steel service, the default

A105N

ASTM A105 normalized

-29 to 425 degrees C

Where notch toughness is specified or the section is thick

LF2

ASTM A350 LF2

About -46 degrees C

Cold service, impact tested as part of the grade

F304 and F316

ASTM A182

-196 to 500 degrees C

Cryogenic, corrosive, or hygienic service

F51 duplex

ASTM A182 F51

-50 to 300 degrees C

Chloride service, offshore, sour with care

F316L

ASTM A182

-196 to 425 degrees C

Welded ends, to avoid sensitisation in the heat affected zone

The temperature column is the mechanical limit and does not account for the medium. F316 in a chloride environment above 60 degrees C is a stress corrosion cracking risk, and duplex F51 should not be taken above about 300 degrees C because of sigma phase formation. LF2 is impact tested at -46 degrees C as part of its specification, which is a genuine advantage over A105 and the reason it appears on cold carbon steel lines.

The floating ball construction is appropriate for this valve up to about 6 inch at Class 600 and 8 inch at Class 150. Above that, the trunnion construction takes over and the extension is designed around a geared operator rather than a lever. A long stem on a trunnion valve is a different assembly, because the extension has to clear the gearbox as well as the insulation.

Insulation, Vapour Barrier and Condensation

An extension that crosses an insulation layer is a thermal bridge, and it is also a path for moisture.

On a hot line the problem is heat loss and personnel protection. The spindle is a steel rod conducting heat out of the insulation, and the handwheel at the top becomes hot enough to need a warning label. The fix is a thermal break in the extension, usually a short section of low conductivity material or an air gap in the sleeve, and a stand-off that puts the handwheel outside the hot zone.

On a cold line the problem is the opposite and it is worse. Moist air reaching cold metal condenses, then freezes, and the ice forms inside the insulation where nobody can see it. The ice then either jams the spindle or, on a cryogenic valve, builds a collar around the gland that tears the packing on the next operation. The vapour barrier has to be continuous around the extension, sealed at the body insulation and at the top plate, and the extension should be vertical with the opening facing down or sealed, so that water cannot run in.

A vertical orientation is not cosmetic. A horizontal extension collects condensate at the low point and puts a bending load on the body joint. A downward extension fills with water. Vertical up is the default, and a specification that requires anything else should say why.

Fire Safe and Anti Blowout in an Extended Assembly

The anti blowout feature is a shoulder on the stem that bears against the body or gland plate, so that the stem cannot be ejected if its retention fails. In an extended assembly the shoulder stays at the bottom, in the body, where it belongs. An extension that relies on a top-mounted retainer for blowout protection is not providing the protection the standard intends, because the joint that fails is the one at the bottom.

Fire safe qualification to API 607 or ISO 10497 is performed on a specific design, size and class. An extension changes the design. A fire certificate for a standard height valve does not automatically cover a 1.5 m extension, because the fire test is measuring the behaviour of the stem seal and the body joint, and a longer stem changes the temperature profile of both. When fire safe is required on a long stem valve, ask whether the certificate covers the extended configuration or only the standard one.

The practical fire safe arrangement is the same as on a standard valve: a graphite secondary seal that survives when the PTFE or elastomer primary seal is consumed, and a metal-to-metal backseat where the design provides one. The extension adds length but does not change the principle, provided the graphite is at the bottom.

Torque, Actuation and the Long Spindle Penalty

Actuator sizing on a long stem valve has to add two terms that a standard valve does not have: the bearing friction of the extension guides, and the torsional deflection allowance.

The guide friction is small per guide but multiplies with the number of guides, and it rises if the spindle is not straight or if the sleeve has filled with grit. In a buried installation with a damaged valve box, grit in the sleeve is common and it can double the operating torque within a few years. Specify sealed guides and a sleeve that drains.

The deflection allowance matters for quarter-turn actuators with limit switches. If the spindle winds up 7 degrees, the actuator has to travel 7 degrees further before the ball moves, and the limit switch that is set on the actuator shaft will report the valve as closed when it is 7 degrees open. The fix is to set the switches on the valve end, or to use a spring return actuator with a torque switch rather than a position switch.

For manual operation, a gear operator is normally fitted above 4 inch or above Class 300, and the gear is mounted at the top of the extension. A chain wheel is used where the operator cannot reach the handwheel, and a extended spindle with a floor stand is used where a platform is not available. All three add their own friction and should be included in the torque budget.

Long stem ball valve with insulation and vapour barrier around the extension

Testing, Certification and the Dimensional Report

The pressure test is the standard sequence applied to the body: shell at 1.5 times the 38 degrees C rating, seat at 1.1 times in both directions, with the extension fitted as it will be supplied. Testing the body without the extension and then fitting it is a common shortcut and it misses the joint that is most likely to leak.

Test or document

What it covers

Why it matters here

Shell test

Body and all pressure joints, 1.5 times rating

Must include the extension joint on the extended bonnet type

Seat test, both directions

1.1 times rating, ISO 5208 rate

Baseline before the valve is buried for a decade

Backseat test

Where the design provides a backseat

Allows packing renewal with the valve in line

Torque test

Break-to-open and running, at the specified differential

Sizes the actuator and detects a bent spindle

Dimensional report

Body centreline to operator face, flange, face-to-face

The extension height is the one dimension that cannot be corrected on site

Material certificate

EN 10204 3.1 by heat and serial

Forging traceability, impact results where applicable

Emission test

ISO 15848 class and temperature band

Fugitive emission compliance, often a permit condition

Fire certificate

API 607 or ISO 10497, with size and class

Confirm it covers the extended configuration

Low emission performance is worth a separate note because it is increasingly a permit condition rather than a preference. ISO 15848-1 classifies stem sealing by measured leak rate and by the number of mechanical and thermal cycles endured. A Class BH rating at ambient is common; a rating that includes thermal cycling to the service temperature is harder and should be specified explicitly if the valve will see temperature swings.

Buried long stem ball valve with the operator reaching grade inside a sealed valve box

Installation of a Buried or Insulated Long Stem Valve

Five points decide whether the installation works.

Set the valve box before the valve. The box position fixes the extension height, and cutting the extension on site to fit a box that is already in the ground is how valves end up with a handwheel at ankle height.

Support the body independently of the pipe. A buried valve on a settlement-prone line will otherwise carry the pipe load through its flanges.

Keep the sleeve clean and drained. A sleeve open at the bottom fills with ground water; a sleeve sealed at both ends traps condensation. The correct arrangement is a sealed box at grade with a drain at the low point of the sleeve.

Do not insulate over the gland on a hot line. The gland needs to be visible and accessible for packing adjustment, and burying it under cladding converts a five minute job into a scaffold job.

Mark the open and closed position at the top, not at the body. On a buried valve the body is invisible, and the only position indication the operator has is at the top of the extension. A gear operator with a position indicator and a travel scale is worth the small extra cost.

How to Specify a Long Stem Ball Valve

  1. State which type: extended spindle for burial, or extended bonnet for thermal service. This is the first line of the enquiry.

  2. Size, class and design temperature range.

  3. Extension length, measured from body centreline to the operator mounting face.

  4. Spindle diameter, or the torque it must transmit, so the supplier can size it.

  5. Where the stem seals sit: body gland plate or top of the extension.

  6. Body material by standard and grade, with impact test requirement.

  7. Ball, stem and seat material, and whether a metal seat is required.

  8. Packing type, fire safe requirement, and whether the certificate must cover the extended configuration.

  9. Guide or steady bearing arrangement, and sleeve diameter if a sleeve is in scope.

  10. Operator type, gear ratio, chain wheel or floor stand, and the actuator torque basis.

  11. Valve box specification, depth of cover and grade level, if the box is in scope.

  12. Test standard, third party witness, dimensional report and certification package.

Typical delivery is 4 to 7 weeks for forged carbon steel in standard sizes, and longer for duplex or for extensions over 2 m where the spindle has to be machined from bar. Drawings are issued for approval before machining, and the extension dimension is confirmed on the drawing rather than assumed from the enquiry.

Spindle guide and steady bearing inside the extension sleeve of a long stem valve

Long Stem Ball Valve FAQ

What is the difference between a long stem ball valve and an extended bonnet ball valve?

In a long stem valve the extension is a spindle inside a sleeve and the pressure boundary stays at the body gland, which is the buried configuration. In an extended bonnet valve the bonnet itself is lengthened and remains a pressure part, which is the cryogenic and high temperature configuration where the packing must sit outside the insulation. Both are sold under the same search term but they are different products with different drawings and different test requirements.

How long should the stem extension be?

For a buried line, from the body centreline to the top of the valve box plus the operator height, typically 0.6 to 1.5 m. For an insulated line, the insulation thickness plus cladding plus handle clearance, typically 150 to 400 mm. For a cold box, the length is set by a heat leak calculation that keeps the gland above 0 degrees C, typically 300 to 600 mm. The dimension is quoted from body centreline to operator mounting face.

Why does a long stem valve become hard to turn?

Three reasons. The guides or steady bearings add friction, and that friction rises if grit enters the sleeve. The spindle winds up torsionally, so the handwheel moves before the ball does. And if the spindle is undersized it bends under an off-centre handwheel load and rubs in the sleeve. Sizing the spindle at one eighth of the extension length for manual operation avoids most of this.

Can the packing be replaced without excavating a buried valve?

Yes, if the stem seals are in the body gland plate, which is the normal buried configuration. The gland plate can be removed and the packing renewed with the line isolated and the valve in place. If the seals are at the top of the extension, they are accessible from grade but the extension is a pressure boundary and the body-to-extension joint has to be broken, which is a different job.

Does a fire safe certificate cover an extended stem valve?

Not automatically. API 607 and ISO 10497 qualification is specific to a design, size and class. An extension changes the stem seal temperature profile, so the certificate should state that it covers the extended configuration. Ask for the certificate and read which configurations it lists.

What is the maximum extension length you can supply?

Extensions of 3 m are practical for manual operation with intermediate guides, and longer extensions are possible with a supported spindle and a designed guide spacing. Beyond about 3 m the torsional wind-up and the buckling load become the governing design cases, and an actuator mounted at the valve with a remote manual override is often the better answer.

What information do you need to quote a long stem ball valve?

Which type, size, class, design temperature, extension length from body centreline to operator face, spindle torque or diameter, seal position, body and trim materials, seat material, packing, fire safe requirement, operator type, valve box details if in scope, test standard and certification. A sketch showing the grade level and the insulation thickness resolves most questions immediately.

Other pages cover the large diameter trunnion construction, the nickel aluminum bronze body for seawater, the reduced bore 8x6 configuration, the jacketed body for media that solidify, and the small bore double block and bleed valve for instrument isolation.

Hot Products

News

Product News

Ball Valves in A Kraft Pulp Mill: Black Liquor, Green Liquor And The Cost of Choosing The Alloy by Habit

White liquor at pH 14 cracks carbon steel welds, black liquor sets solid below 100 C, green liquor dregs grind seats: alloy choice and torque in a kraft mill.

Read More
Ball Valves in A Kraft Pulp Mill: Black Liquor, Green Liquor And The Cost of Choosing The Alloy by Habit
Product News

Slug Flow And Ball Valves: What Actually Arrives At The Seat

A slug is liquid mass with momentum, not a pressure spike. What changes at the seat, in the cavity and at the actuator when liquid reaches a ball valve.

Read More
Slug Flow And Ball Valves: What Actually Arrives At The Seat
Product News

Ball Valves in Direct Lithium Extraction: PH 1 Eluate, Gypsum Scale And 438,000 Cycles in Twenty-Five Years

Direct lithium extraction swings valves from pH 1 eluate to pH 12 caustic, 48 column switches a day and gypsum scale. Materials, seats and torque.

Read More
Ball Valves in Direct Lithium Extraction: PH 1 Eluate, Gypsum Scale And 438,000 Cycles in Twenty-Five Years
Product News

Ball Valves in Geothermal Brine: Silica Scale, Chloride Cracking And The Cooling Trap

Why geothermal brine destroys ball valves: retrograde silica scale, calcite at the flash point, chloride cracking above 60 C and the 250 C seat limit.

Read More
Ball Valves in Geothermal Brine: Silica Scale, Chloride Cracking And The Cooling Trap